Pressure reducing valve
The pressure regulator valve regulates the compressed air supply to the preset nominal pressure and equalizes pressure fluctuations. The compressed air is discharged via connection 3 when the pressure at connection 2 exceeds the nominal pressure. The setting for the real components is component dependent and cannot be changed.
Adjustable parameters
| Designation | Range | Default value |
|---|---|---|
| Nominal pressure | 0 ... 2 MPa | 0.4 |
| Pressure regulation range | 0.01 ... 1 MPa | 0.05 |
| Standard nominal flow rate | 0.1 ... 5000 l/min | 300 |