Analog flow meter
This symbol represents the hydraulic part of the analog flow meter. The analog flow meter measures the volumetric flow and transforms it into a proportional electrical voltage signal. In the process, only flow rates in the specified pressure ranges are considered. Within this range, the flow rate in the voltage range from 0 V to 10 V is represented, i.e. the minimum volumetric flow delivers 0 V and the maximum volumetric flow 10 V.
Adjustable parameters
| Designation | Range | Default value |
|---|---|---|
| Flow Direction | Ignore, Consider | Ignore |
| Flow rate (min) | -500 ... 500 l/min | 0 |
| Flow rate (max) | -500 ... 500 l/min | 10 |
| Voltage (q1) | -100 ... 100 V | 0 |
| Voltage (q2) | -100 ... 100 V | 10 |
| Designation | Range | Default value |
|---|---|---|
| Hydraulic resistance | 1e-6 ... 1000 bar.min2/l2 | 0.001 |